ISO 8573 compressed air quality testing instrument

ISO 8573 Purity Compliance & Validation

Compressed Air Quality Testing
& Purity Audits

Protect product quality, avoid batch contamination, and pass quality audits. Fisher Installations delivers calibrated ISO 8573 testing for particles, dew point moisture, oil vapor, and bacteria.

ISO 8573Global air purity standard
-40°CtdPressure dew point testing
100%Audit-ready certificates

Accredited testing parameters

Four key compressed air purity parameters we measure

Where compressed air contacts food, pharmaceuticals, or delicate components, unmonitored contaminants cause corrosion, bacteria growth, and audit failures.

Solid Particles

Laser particle counter analysis classifying particle size counts down to 0.1 – 0.5 µm, 0.5 – 1.0 µm, and 1.0 – 5.0 µm.

Pressure Dew Point

Calibrated dew point sensors measure dryness down to -40 °Ctd (desiccant dry) or +3 °Ctd (refrigerated dry).

Oil Aerosols & Vapor

Testing total residual oil concentration (mg/m³) across systems equipped with activated carbon towers or oil-free compressors.

Microbial Contaminants

Sterile air sampling ensuring airlines feeding packaging areas are free from live bacteria, yeasts, and fungal spores.

Regulatory compliance

ISO 8573-1:2010 Purity Class Matrix

Purity Class Particle Count (0.1–0.5 µm) Pressure Dew Point (°Ctd) Total Oil (mg/m³)
Class 0 As specified by equipment user / stricter than Class 1 Stricter than Class 1 Stricter than Class 1 (< 0.01 mg/m³)
Class 1 ≤ 20,000 / m³ ≤ -70 °Ctd ≤ 0.01 mg/m³
Class 2 ≤ 400,000 / m³ ≤ -40 °Ctd ≤ 0.1 mg/m³
Class 3 Not specified ≤ -20 °Ctd ≤ 1.0 mg/m³
Class 4 Not specified ≤ +3 °Ctd ≤ 5.0 mg/m³
Air Quality Deliverable

A formal Certificate of Conformance mapping measured solid particles, pressure dew point (°Ctd), and total oil concentration directly against ISO 8573-1:2010 quality class limits.

Frequently asked questions

Air quality testing FAQs

How long does on-site compressed air quality testing take?

On-site sampling typically takes 2 to 4 hours per designated testing point. Results for dew point and particle counts are available immediately, while microbial culture plates undergo lab incubation.

Do I receive a formal Certificate of Analysis?

Yes. You receive an official Fisher Certificate of Conformance mapping measured values directly against ISO 8573-1:2010 quality class thresholds for your quality management audit files.